Default welcome msg!

GLOBAL SITE
(please select your language)
en de fr es ITALIAN SITE
| USA SITE

us

Sulcoflex® Pseudophakic Supplementary IOLs

Share:

As a cataract and refractive surgeon, achieving the best possible visual results for your patients is paramount. But sometimes, even the best patient selection and most accurate work can result in refractive surprises.   

Wouldn’t it be great to have a lens that offers you more than one shot? An option that is reversible? Rayner Sulcoflex Pseudophakic Supplementary IOLs are designed to be implanted in the ciliary sulcus to correct any residual post-operative refractve errors following the implantation of a conventional IOL in the capsular bag.

To learn more about the Rayner supplementary IOL platform please click here

Detailed Product Information

Sulcoflex Patient Benefits

Innovative Design

Hydrophilic acrylic injectable IOLs with undulating haptics and posterior haptic angulation

Rayner Sulcoflex Pseudophakic Supplementary IOLs are designed to be implanted in the ciliary sulcus to correct any residual post-operative refractive errors following the primary implantation of a conventional IOL in the capsular bag*.

* An iridotomy/iridectomy may be necessary.

 

Indications1, 4

  • Post-surgical ametropia
  • Enhancement of the refractive result after RLE or PRELEX
  • Enhancement of near / far vision
  • Correction of pseudophakic presbyopia
  • Correction of residual pseudophakic astigmatism
  • Extreme myopia or hyperopia
  • Patients experiencing a dynamic change of refraction
  • For the refractive correction of patients without biometry readings.

Avoids the potential problems of conventional "piggy-back" IOLs1, 4

  • Unique posterior concave surface, minimises the possibility of interaction with the primary IOL
  • Reduced likelihood of unwanted photopic effects
  • Reduced refractive error with hyperopic defocus.
Physical contact between the two IOLs minimised.

 

Reduced surgical risk associated with IOL exchange 1, 4

  • Less surgical trauma than primary IOL exchange
  • Avoids sometimes difficult removal of fibrosed, fixated primary implant.

Large 6.5mm round-edged optic

  • Optimal visual outcomes
  • Reduced risk of optic-iris capture
  • Minimal edge glare and associated dysphotopsia.
 

Large 14.0mm Overall Length with Undulating Haptics

  • Unique undulating round edge haptic design with 10° angulation
  • Excellent centration and rotational stability**
  • Reduced risk of uveal contact and abrasion
  • Reduced Pigment Dispersion Syndrome
  • Smooth undulating haptics to minimise the risk of adverse tissue reaction in the sulcus.
2 Adequate iris-IOL and IOL-IOL distance.
** Unusual or irregular anatomy of the ciliary sulcus may cause a post-operative rotational displacement of the IOL.


References:
1. Claoué C. Clinical and Surgical Ophthalmology 2008; 26(6): 198-200.
4. Nanavaty MA et al. JCRS 2009; 35(4): 663-71

Sulcoflex Aspheric / Sulcoflex Multifocal / Sulcoflex Toric / Sulcoflex Multifocal Toric

Sulcoflex Multifocal (653F)

Sulcoflex Multifocal IOLs are indicated for the correction of pseudophakic presbyopia, thereby significantly reducing the need for additional near correction by the use of spectacles or contact lenses.

Based on Rayner's refractive aspheric optic technology, near vision is achieved by the addition of +3.5 D at the IOL plane in a far dominant format.

Sulcoflex Aspheric (653L)

Sulcoflex Aspheric IOLs are indicated for the correction of any residual pseudophakic ametropia. With the Standard range from –5.0 D to +5.0 D and the Premium range extending from –10.0 D to +10.0 D, Sulcoflex Aspheric IOLs offer an effective option for the resolution of post-operative myopic or hypermetropic refractive surprises.

 

Sulcoflex Toric (653T)

Sulcoflex Toric IOLs are indicated for the correction of any residual pseudophakic corneal astigmatism.

The implantation of a Sulcoflex Toric IOL offers a precise and reliable alternative to corneal surgery and is available in a range of sphere / cylinder combinations. The unique undulating haptic design improves rotational stability leading to optimal toric corrections.

Sulcoflex Multifocal Toric (653Z)

Sulcoflex Multifocal Toric IOLs are indicated for the correction of pseudophakic presbyopia in combination with residual corneal astigmatism. The refractive aspheric optic offers a near addition of +3.5 D at the IOL plane in a far dominant format and a toric correction of +1.0 D, +2.0 D and +3.0 D cylinders. The undulating haptic design improves rotational stability for precise optimal corrections.

 

Sulcoflex Technical Specifications and Presentation

 
  Model Name Model Number Power Range Increments Addition Optic Diameter Over Length Haptic Angulation Optic Configuration  
  Sulcoflex
Aspheric
653L
Standard
Power Range
-5.0 to -0.5 D
+0.5 to +5.0 D
0.5 D   6.50mm 14.00mm 10° Anterior convex,
Posterior concave
 
  653L
Made to Order
Power Range
-10.0 to -5.5 D
+5.5 to +10.0 D
0.5 D   6.50mm 14.00mm 10° Anterior convex,
Posterior concave
 
  Sulcoflex
Multifocal
653F
Standard
Power Range
-3.0 to +3.0 D 0.5 D +3.5 D
add far
dominant
6.50mm 14.00mm 10° Anterior convex,
posterior concave
 
  653F
Made to
Order

Power Range
-7.0 to -3.5 D
+3.5 to +7.0 D
0.5 D +3.5 D
add far
dominant
6.50mm 14.00mm 10° Anterior convex,
posterior concave
 

 

 
  Model Name Model Number Power Range Increments Addition Optic Diameter Over Length Haptic Angulation Optic Configuration  
  Sulcoflex
Toric
653T
Standard
Power Range

Spherical Equivalent
-3.0 to +3.0 D

 


0.5 D

 

  6.50mm 14.00mm 10° Anterior convex,
posterior concave
 
Cylinders
+1.0 D, +2.0 D,
+3.0 D
 
  653T
Made to
Order

Power Range

Spherical Equivalent
-7.0 to +7.0 D

Cylinders
+1.0 to +6.0 D

0.5 D

0.5 D

  6.50mm 14.00mm 10° Anterior convex,
Posterior concave
 
  Sulcoflex
Multifocal Toric
653Z
Standard
Power Range

Spherical Equivalent
-3.0 to +3.0 D

Cylinders
+1.0 D, +2.0 D,
+3.0 D

0.5 D

 

+3.5 D
add far
dominant
6.50mm 14.00mm 10° Anterior convex,
posterior concave
 
  653Z
Made to
Order

Power Range

Spherical Equivalent
-7.0 to +7.0 D

Cylinders
+1.0 to +6.0 D

0.5 D

0.5 D

+3.5 D
add far
dominant
6.50mm 14.00mm 10° Anterior convex,
posterior concave
 

 

  Product Name Model No. Presentation

 

Sulcoflex Aspheric

653L

System Pack with Single Use Soft-Tipped Injector

Sulcoflex Multifocal 

653F

System Pack with Single Use Soft-Tipped Injector

Sulcoflex Toric

653T

System Pack with Single Use Soft-Tipped Injector

Sulcoflex Multifocal Toric

653Z

System Pack with Single Use Soft-Tipped Injector

Sulcoflex Regulatory

Not all products or offerings are approved or offered in every market and approved labelling and instructions may vary from one country to another. For country specific product information contact your local distributor or email iol_enquires@rayner.com.

This product is not approved by the FDA for use or distribution in the United States of America.

Rayner hold a selection of EC certificates for various products. Please contact the Regulatory Affairs team for the current version.

What Other Surgeons Have Also Viewed

Webpage: Rayner Supplementary Platform

View

Sulcoflex Product Portfolio

Download

ESCRS Supplement 2015

Download

Rayner Supplement: Maximising Treatment Options with Premium IOL Technology

Download

Webpage: Ophteis® FR Pro

View

Webpage: RaySert PLUS

View

Refractive Surprises – Are They Really Taboo?

View

Rayner's Recently Acquired Ophteis OVD Range

View

Long-Term Experience with Rayner’s Sulcoflex® Lens

View

The Rayner Sulcoflex® Lens: A Predictable Yet Reversible Multifocal Solution

View

News: Sulcoflex Now Available in Korea

View

News: Sulcoflex an excellent solution in correcting residual refractive error

View

News: Sulcoflex toric excellent long term visual outcomes

View